Infinity Machine International Inc.
Infinity Machine International Inc.
Infinity Machine International Inc.

Tel: +86-(0)769-87796906
Fax: +86-(0)769-83428065
Contact: travis lau
E-mail:
travis.lau@infinity-machine.com
Website: www.infinity-machine.com
Factory Add: No.103 Building 4, Furong Industrial Center, Wangniudun Town, 523200, Dongguan City, China

Infinity Machine International Inc.
Temperature Humidity Test Chamber
Temperature Humidity Test Chamber
1

Name:Low Humidity and Temperature Humidity Test Chamber

零售价
0.0
Yuan
市场价
0.0
Yuan
浏览量:
1000
Model:
IN-TM408L / IN-TM800L
数量
-
+
库存:
0
1
Purpose
Specification
Advantages
Accessories
Software
Video
Similar Products

 

Name: Low Humidity and Constant Temperature Humidity Test Chamber

 

Model: IN-TM408L / IN-TM800L

 

Purpose:

 

In addition to testing whether the adaptability and characteristics of the product had been changed under the general conditions of temperature and humidity combination (high-low temperature operation & storage, temperature cycling, high temperature and high humidity or moisture condensation test) by simulatable products, low humidity and constant temperature-humidity test chamber can also test whether the crazing and breakage of the product would happen under the conditions of low temperature and low humidity, high temperature and low humidity, high temperature and high humidity or low temperature and low humidity. Furthermore, the static content in air under the low humidity condition is many times more than the general condition, and it is said that most damage of the electronic components is caused by static.

Meeting the requirements of international specification test (IEC, JIS, GB, MIL...) to ensure the consistency of international measurement programs (including testing procedures, conditions and methods) to avoid cognitive differences and reduce the measurement uncertainties.

关键词:
Temperature Humidity Test Chamber
Temperature Humidity Test Machine
Temperature Humidity Test Room
Temperature Humidity Chamber

 

Test specification:

 

a. Specification required for condensation and non-condensation tests can be performed.

b. Technology of temperature and humidity synchronization slope control of test sample non-condensation test.

c. Drying phase test conditions before condensation test can be performed.

 

Test condition:

 

5%RH10℃/5%RH, 20℃/5%RH, 50℃/5%RH
10%RH: 10℃/10%RH, 15℃/10%RH, 25℃/10%RH, 30℃/10%RH, 65℃/10%RH
15%RH: 10℃/15%RH
20%RH: 20℃/20%RH, 85℃/20%RH, 75℃/20%RH, 65℃/20%RH

40%RH: 25℃/40%RH

90%RH: 65℃/90%RH

 

a

 

Specification:

 

Model

IN-TM408L

IN-TM800L

Interior size (mm)

W800xH850xD600

W1000×H1000×D800

Exterior size (mm)

W1000xH1950xD1900

W1200xH1900xD2100

Power supply

AC380V 5Ø 10kW

AC380V 5Ø 12kW

Humidity range

5 ~ 98 %

Equilibrium of temp. distribution

±1.0℃(-40℃~100℃) /±1.5℃(-40.0~-70℃100.0~150℃

Equilibrium of humid. distribution

±5 %RH (center point)

Temp. accuracy

± 0.2  ℃

Humid. accuracy

±2 %RH

Temp. resolution

± 0.01  ℃

Humid. resolution

± 0.1 %

Heating up time

45minutes for 25℃~150℃, the whole process is average nonlinear, no-load

Cooling down time

50minutes for 20℃~-40℃, the whole process is average nonlinear, no-load

Noise

70dB(A)

Meeting standard

GB/T2423.1-2008(IEC60068-2-1:2007);

GB/T2423.2-2008(IEC60068-2-2:2007);

GJB150.3-1986;

CJB150..4-1986;

GB/T2423.3-2006(IEC60068-2-78:2007)GB/T2423.4-2;008(IEC60068-2-30:2005);

GB/T2423.34-2005;

 

 

Feature: 

 

Ø An effective low humidity control range of 10℃/5%RH.

Ø Relevant low temperature and low humidity tests can be performed.

Ø A technology of long-time operation and radiating under the condition of ultra-low humidity without frosting.

Ø Adopting the fast Swedish dehumidification, Munters dehumidifier is more suitable for using under low humidity environment. It

      is equipped with a sealed desiccant wheel made of heat-resisting material. Such structure not only ensures the

      dehumidification, the regeneration and the precise balance of heat recycle airflow, but also effectively reduces the energy  

      consumption.

 

   f

 

Ø Adopt the Finland VAISALA electronic humidity sensor to measure the humidity change, which is reliable and highly accurate.

 

      f

 

Ø Several protection measures of over-temperature protection, over-pressure protection, water-lack protection and phase-lack

       protection.

Ø Warning measures of water-lack warning for machine water storage tank and dry burning-resistant warning for humidifier.

Ø SD card digital recorders are provided for copying the test data or test curves.

Ø iOs APP remote monitoring function allows you to monitor the operation of the machine by mobile phone even when you are on

       a business trip.

 

       f

 

Video: 

 

Please help to contact us for more details.

搜索

Contact Us

+86-(0)769-83428065

NO.103 Building 4,No.27,Beihuan Road,Wangniudun Town,Dongguan City,Guangdong Province,China

东莞市万材智能设备有限公司   Copyright  Since 1998-2016   粤ICP备08132298号   Powered by www.300.cn